COVID-19 Research Paper Volume 13, Issue 10 pp 13393—13404

Dynamic changes in coagulation parameters and correlation with disease severity and mortality in patients with COVID-19

class="figure-viewer-img"

Figure 1. A scatter plots of the coagulation values on hospital admission between severe and non-severe patients. The severe patients had a slightly higher INR (1.02 vs 0.99, p = 0.016), PT (13.6s vs 13.2s, p = 0.019), APTT (42.1s vs 38.4s, p = 0.019), whereas remarkably higher FDP (2.03 vs 0.65 ug/ml, p < 0.001) and D-dimer (0.87 vs 0.27 ug/ml, p < 0.001) than non-severe patients.